Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	47
Date	08/12/14
Start Time	10:56:45
Diameter Midpoint
 10.9	911.782
 11.3	67780.7
 11.8	367103
 12.2	401786
 12.6	444498
 13.1	490126
 13.6	544341
 14.1	591396
 14.6	631130
 15.1	681099
 15.7	725198
 16.3	765762
 16.8	798408
 17.5	824300
 18.1	837284
 18.8	843730
 19.5	834707
 20.2	812091
 20.9	777036
 21.7	733823
 22.5	679977
 23.3	621617
 24.1	551057
 25.0	483157
 25.9	410988
 26.9	337894
 27.9	268159
 28.9	210236
 30.0	157575
 31.1	114332
 32.2	82934.2
 33.4	58469.1
 34.6	42222.7
 35.9	30038
 37.2	20881.5
 38.5	14590
 40.0	9941.43
 41.4	6901.24
 42.9	4967.86
 44.5	3751.09
 46.1	2828.22
 47.8	1953.77
 49.6	1490.59
 51.4	1145.44
 53.3	982.804
 55.2	697.885
 57.3	524.661
 59.4	440.991
 61.5	340.101
 63.8	251.897
 66.1	258.903
 68.5	194.729
 71.0	220.586
 73.7	186.772
 76.4	170.44
 79.1	170.574
 82.0	148.887
 85.1	112.65
 88.2	104.916
 91.4	82.7232
 94.7	87.4548
 98.2	75.4642
101.8	86.7387
105.5	53.1764
109.4	73.5164
113.4	57.8477
117.6	70.8048
121.9	69.0768
126.3	48.8737
131.0	57.5526
135.8	58.7212
140.7	56.3801
145.9	39.7206
151.2	34.8459
156.8	40.7041
162.5	42.6139
168.5	51.2242
174.7	33.7883
181.1	36.5178
187.7	44.6822
194.6	31.7563
201.7	19.5882
209.1	35.8722
216.7	17.2703
224.7	19.687
232.9	32.298
241.4	25.8091
250.3	42.7003
259.5	37.6357
269.0	9.18106
278.8	18.9825
289.0	8.49771
299.6	6.06197
310.6	12.4117
322.0	22.0911
333.8	16.6178
346.0	13.6576
358.7	7.59589
371.8	9.94235
385.4	4.49829
399.5	4.55235
414.2	6.95677
429.4	2.36342
445.1	2.39361
461.4	9.76515
478.3	2.49101
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1777
High Voltage	9864.71
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	18.4192
Mean(nm)	19.1396
Geo. Mean(nm)	18.5163
Mode(nm)	18.7688
Geo. Std. Dev.	1.28862
Total Concentration(#/cm)	1.6296e+007
Comment	